Configuring HanDreamnet (HDN) Security Switch Connectors
You can connect Stellar Cyber to a HanDreamnet (HDN) switch and block an IP address from within Stellar Cyber, while you are threat hunting.
Connector Overview: HanDreamnet
Capabilities
-
Collect: No
-
Respond: Yes
-
Native Alerts Mapped: No
-
Runs on: DP or Sensor
-
Interval: 5 minutes
Collected Data
N/A
Domain
https://<Device IP Address> where <Device IP Address> is a variable from the configuration of this connector |
Response Actions
Action |
Required Fields |
---|---|
|
Third Party Native Alert Integration Details
N/A
Required Credentials
-
Device IP Address and Token
Let us know if you find the above overview useful.
Adding an HDN Connector
To add a new HDN connector:
Obtaining HanDreamnet Credentials
To configure this connector you must first obtain the following information:
-
The Device IP address of the switch
-
An API Token
Adding the Connector in Stellar Cyber
To add a HanDreamnet connector in Stellar Cyber:
-
Log in to Stellar Cyber.
-
Click System | Integration | Connectors. The Connector Overview appears.
-
Click Create. The General tab of the Add Connector screen appears. The information on this tab cannot be changed after you add the connector.
The asterisk (*) indicates a required field.
-
Choose Security Switch from the Category drop-down.
-
Choose HanDreamnet Security Switch from the Type drop-down.
-
For this connector, the supported Function is Respond, which is enabled already.
-
Enter a Name.
Notes:- This field does not accept multibyte characters.
- It is recommended that you follow a naming convention such as tenantname-connectortype.
-
Choose a Tenant Name. The Interflow records created by this connector include this tenant name.
-
Choose the device on which to run the connector.
-
Click Next. The Configuration tab appears.
The asterisk (*) indicates a required field.
-
Enter the Device IP Address to access the switch.
-
Enter the Token you obtained in the previous section.
-
Click Next. The final confirmation tab appears.
-
Click Submit.
The new connector is immediately active.
Testing the Connector
When you add (or edit) a connector, we recommend that you run a test to validate the connectivity parameters you entered. (The test validates only the authentication / connectivity; it does not validate data flow).
For connectors running on a sensor, Stellar Cyber recommends that you allow 30-60 seconds for new or modified configuration details to be propagated to the sensor before performing a test.
-
Click System | Integrations | Connectors. The Connector Overview appears.
-
Locate the connector that you added, or modified, or that you want to test.
-
Click Test at the right side of that row. The test runs immediately.
Note that you may run only one test at a time.
Stellar Cyber conducts a basic connectivity test for the connector and reports a success or failure result. A successful test indicates that you entered all of the connector information correctly.
To aid troubleshooting your connector, the dialog remains open until you explicitly close it by using the X button. If the test fails, you can select the button from the same row to review and correct issues.
The connector status is updated every five (5) minutes. A successful test clears the connector status, but if issues persist, the status reverts to failed after a minute.
Repeat the test as needed.
If the test fails, the common HTTP status error codes are as follows:
HTTP Error Code | HTTP Standard Error Name | Explanation | Recommendation |
---|---|---|---|
400 | Bad Request | This error occurs when there is an error in the connector configuration. |
Did you configure the connector correctly? |
401 | Unauthorized |
This error occurs when an authentication credential is invalid or when a user does not have sufficient privileges to access a specific API. |
Did you enter your credentials correctly? Are your credentials expired? Are your credentials entitled or licensed for that specific resource? |
403 | Forbidden | This error occurs when the permission or scope is not correct in a valid credential. |
Did you enter your credentials correctly? Do you have the required role or permissions for that credential? |
404 | Not Found | This error occurs when a URL path does not resolve to an entity. | Did you enter your API URL correctly? |
429 | Too Many Requests |
This error occurs when the API server receives too much traffic or if a user’s license or entitlement quota is exceeded. |
The server or user license/quota will eventually recover. The connector will periodically retry the query. If this occurs unexpectedly or too often, work with your API provider to investigate the server limits, user licensing, or quotas. |
For a full list of codes, refer to HTTP response status codes.