Configuring Trellix MVISION Connectors
This connector allows Stellar Cyber to ingest logs from Trellix MVISION and add the records to the data lake. It integrates with the Trellix MVISION EDR API to query for Insight events and devices.
Stellar Cyber connectors with the Collect function (collectors) may skip collecting some data when the ingestion volume is large, which potentially can lead to data loss. This can happen when the processing capacity of the collector is exceeded.
Connector Overview: Trellix MVISION
Capabilities
-
Collect: Yes
-
Respond: No
-
Native Alerts Mapped: No
-
Runs on: DP
-
Interval: Configurable
Collected Data
Content Type |
Index |
Locating Records |
---|---|---|
Devices Insight Events |
Syslog Assets (for Devices) |
Domain
N/A
Response Actions
N/A
Third Party Native Alert Integration Details
N/A
Required Credentials
-
API Key, Client ID, and Client Secret
Let us know if you find the above overview useful.
Adding a Trellix MVISION Connector
To add a Trellix MVISION connector:
Obtaining Trellix MVISION Credentials
Before you configure the connector in Stellar Cyber, you must obtain the following Trellix MVISION credentials:
-
API key
-
Client ID
-
Client secret
The client credentials are available in your Trellix on-boarding email. However, you can follow these steps to generate credentials again:
-
Log in to Trellix Developer Portal as an administrative user.
-
Navigate to Self Service | API Access Management.
-
Copy the API key, which you will need when configuring the connector in Stellar Cyber.
Store the API key in a safe location. It cannot be retrieved later although it can be regenerated.
-
In the Credential Configurations section, enter your Client Type, select the required APIs and Method Types.
-
Click Request. When the request is approved, the Create Client Credentials section appears on the page.
-
Click Generate Again to generate the client credentials.
-
Copy the Client ID and Client Secret, which you will need when configuring the connector in Stellar Cyber.
Adding the Connector in Stellar Cyber
To add a Trellix MVISION connector in Stellar Cyber:
-
Log in to Stellar Cyber.
-
Click System | Integrations | Connectors. The Connector Overview appears.
-
Click Create. The General tab of the Add Connector screen appears. The information on this tab cannot be changed after you add the connector.
The asterisk (*) indicates a required field.
-
Choose Endpoint Security from the Category drop-down.
-
Choose Trellix MVISION Endpoint Security from the Type drop-down.
-
For this connector, the supported Function is Collect, which is enabled already.
-
Enter a Name.
Notes:- This field does not accept multibyte characters.
- It is recommended that you follow a naming convention such as tenantname-connectortype.
-
Choose a Tenant Name. This identifies which tenant is allowed to use the connector.
-
Choose the device on which to run the connector.
-
(Optional) When the Function is Collect, you can apply Log Filters. For information, see Managing Log Filters.
-
Click Next. The Configuration tab appears.
The asterisk (*) indicates a required field.
-
Enter the API Key you noted above in Obtaining Trellix MVISION Credentials.
-
Enter the Client ID you noted above.
-
Enter the Client Secret you noted above.
-
Choose the Interval (min). This is how often the logs are collected.
-
Choose the Content Type you would like to collect. The logs for Devices and Insight Events are supported.
The Devices content type is always selected and cannot be removed from the configuration as it is required for host information.
-
Click Next. The final confirmation tab appears.
-
Click Submit.
To pull data, a connector must be added to a Data Analyzer profile if it is running on the Data Processor.
The new connector is immediately active.
Testing the Connector
When you add (or edit) a connector, we recommend that you run a test to validate the connectivity parameters you entered. (The test validates only the authentication / connectivity; it does not validate data flow).
For connectors running on a sensor, Stellar Cyber recommends that you allow 30-60 seconds for new or modified configuration details to be propagated to the sensor before performing a test.
-
Click System | Integrations | Connectors. The Connector Overview appears.
-
Locate the connector that you added, or modified, or that you want to test.
-
Click Test at the right side of that row. The test runs immediately.
Note that you may run only one test at a time.
Stellar Cyber conducts a basic connectivity test for the connector and reports a success or failure result. A successful test indicates that you entered all of the connector information correctly.
To aid troubleshooting your connector, the dialog remains open until you explicitly close it by using the X button. If the test fails, you can select the button from the same row to review and correct issues.
The connector status is updated every five (5) minutes. A successful test clears the connector status, but if issues persist, the status reverts to failed after a minute.
Repeat the test as needed.
If the test fails, the common HTTP status error codes are as follows:
HTTP Error Code | HTTP Standard Error Name | Explanation | Recommendation |
---|---|---|---|
400 | Bad Request | This error occurs when there is an error in the connector configuration. |
Did you configure the connector correctly? |
401 | Unauthorized |
This error occurs when an authentication credential is invalid or when a user does not have sufficient privileges to access a specific API. |
Did you enter your credentials correctly? Are your credentials expired? Are your credentials entitled or licensed for that specific resource? |
403 | Forbidden | This error occurs when the permission or scope is not correct in a valid credential. |
Did you enter your credentials correctly? Do you have the required role or permissions for that credential? |
404 | Not Found | This error occurs when a URL path does not resolve to an entity. | Did you enter your API URL correctly? |
429 | Too Many Requests |
This error occurs when the API server receives too much traffic or if a user’s license or entitlement quota is exceeded. |
The server or user license/quota will eventually recover. The connector will periodically retry the query. If this occurs unexpectedly or too often, work with your API provider to investigate the server limits, user licensing, or quotas. |
For a full list of codes, refer to HTTP response status codes.
Verifying Ingestion
To verify ingestion:
-
Click Investigate | Threat Hunting. The Interflow Search tab appears.
-
Change the Indices for the type of content you collected:
-
For Insight Events and Devices, change the Indices to Syslog.
-
For Devices only, change the Indices to Assets.
The table immediately updates to show ingested Interflow records.
-