Virtual Appliance Sizing Specifications

This article describes the resources required for the successful installation and operation of Stellar Cyber virtual appliances (sensors, aggregators, and DPs).

Stellar Cyber Virtual 50 Sizing Specifications

You can install Stellar Cyber as a Virtual 50 appliance (All-In-One) on a VM. The VM must have at least:

Component Specification

Virtual Cores

16 (verified on Xeon Gold processors @ 2.10 GHz)

RAM (GB)

128

OS SSD Disk Space (GB)

500

Data Lake SSD Disk Space (TB)

2

Network Interfaces

1 x 1 GB

You can also install Stellar Cyber on a dedicated VMware ESXi server with support for up to 300GB of daily ingestion. In this model, you install as an integrated DP, with separate VMs for the DA and DL.

Sensor Specifications

You can install modular, security, network, container, and server (agent) sensors. Security and network sensors install as dedicated VMs; container sensors install as containers. Server sensors install as applications in an existing VM (Linux or Windows).

See the following sections for details:

Provision Sufficient Resources for Virtual Sensors!

In order to guarantee the performance of your virtual sensors, you must provision them according to the system requirements for CPUs and memory in the sections that follow. For hypervisors that allow it, this includes reserving resources.

In addition, pay attention to the clock speed for provisioned processors. Stellar Cyber validates sensor installations on processors @ 2.10 GHz.

The procedure below provides instructions on how to reserve resources in a VMware environment.

Other hypervisors may provide their own tools for reserving resources. Refer to your hypervisor's documentation for details. In general, Stellar Cyber recommends reserving resources wherever possible to guarantee sensor performance.

Modular Sensor Specifications

A modular sensor lets you easily add the features you like to your sensor. This helps simplify your deployment and lets you manage the VM requirements for the sensors based on the modular features they use. A modular sensor is also recommended by Stellar Cyber when you want to deploy an aggregator – simply enable the Aggregator feature in its Modular Sensor Profile.

The modular sensor VM must meet the minimum specifications in the table below:

Modular Features Virtual Cores RAM (GB) SSD (GB) Workers
Log forwarder (500 events/s) 1 3 64 1
Log forwarder and aggregator (500 events/s; 100 Mbps traffic) 1 3 64 1

The OVA/VHD files distributed for Modular Sensor installation in VMware/Hyper-V environments provision the VM with 1 virtual core, 3 GB of RAM, and a 64 GB disk. You must provision sufficient resources to support the features you anticipate enabling for the Modular Sensor in its Modular Sensor Profile. Use the table below to determine the total resources required for different combinations of the features available in a Modular Sensor Profile.

As a rule of thumb, Stellar Cyber recommends that you provision at least 1.5 times as much memory as the number of CPU cores to ensure stable performance. So, for example, if you provision 8 CPUs, you should provision at least 8 x 1.5 = 12 GB of memory.

CPU RAM (GB) Disk (GB)

Log Collector
Log Forwarder

Network Traffic

IDS

Sandbox

Tenable

1 3 23 ü
2 3 28 ü ü
4 6 50 ü ü ü
4 6 50 ü ü ü
4 6 50 ü ü ü ü
2 4 33 ü ü
3 5 38 ü ü ü

4

8

60

ü ü ü ü

4

8

60

ü ü ü ü

4

8

60

ü ü ü ü ü

Keep in mind the following:

  • Log Collector and Log Forwarder are always enabled in Modular Sensor Profiles.

  • (missing or bad snippet)
  • The Sandbox and IDS features can only be enabled if Network Traffic is enabled.

  • Modular Sensor throughput is the same as stated for Security Sensors when provisioned similarly.

Network Sensor Specifications

The network sensor VM must have at least:

Component 250M Network Sensor 1G Network Sensor
Virtual Cores (reserved) 4 12
RAM (GB) (reserved) 8 32
SSD (GB) 64 128
Maximum traffic inspection throughput (Mbps)*
(1 or 2 span ports)
250 1,000
Log Forwarder Workers 4 8
Log Forwarder Events/s 1,500 7,000

Stated specifications support the corresponding maximum network traffic inspection throughput. Performance may vary depending on your environment, configuration, and other variables.

Note the following for Network Sensor installations:

  • The network sensor specs assume a span port, local file assembly, packet forwarding, and log forwarding.

  • Starting with the 4.3.5 release, you no longer need to provision log forwarder workers manually in the Sensor Profile. Instead, Stellar Cyber automatically spawns the appropriate number of Log Forwarder Workers based on the VM's provisioning.

  • Note that the OVA/VHD files distributed for Network Sensor installation in VMware/Hyper-V environments provision the VM with 4 virtual cores, 8 GB of RAM, and a 64 GB disk (the 250M Security Sensor model in the table above). If you want to use one of the other models, you must reconfigure your virtual machine after installation to match the stated specifications.

  • Both the virtual cores and the RAM assigned to the Network Sensor virtual machine must be reserved for the VM's use.

Security Sensor Specifications

The security sensor VM must have at least:

Component

200M Security Sensor

500M Security Sensor

1G Security Sensor 10G Security Sensor
Virtual Cores (reserved)

4

8

12 24
RAM (GB) (reserved)

8

16

32 64
SSD (GB)

128

128

128 512
Maximum traffic inspection throughput (Mbps)*
(1 or 2 span ports)

200

500

1,000 10,000
Log Forwarder Workers

4

4

8 20
Log Forwarder Events/s

1,500

1,500

7,000 10,000

*Stated specifications support the corresponding maximum network traffic inspection throughput. Performance may vary depending on your environment, configuration, and other variables.

Note the following for Security Sensor installations:

  • The security sensor specs assume a span port, local file assembly, log forwarding, sandbox, and IDS.

  • Starting with the 4.3.5 release, you no longer need to provision log forwarder workers manually in the Sensor Profile. Instead, Stellar Cyber automatically spawns the appropriate number of Log Forwarder Workers based on the VM's provisioning.

  • The OVA/VHD files distributed for Security Sensor installation provision the VM with 12 virtual cores, 32 GB of RAM, and a 128 GB disk (the 1G Security Sensor model in the table above). If you want to use one of the other models, you must reconfigure your virtual machine after installation to match the stated specifications.

  • Both the virtual cores and the RAM assigned to the Security Sensor virtual machine must be reserved for the VM's use.

Linux Server Sensor Specifications

The Linux Server Sensor uses 5% of the host server's resources, including each CPU core, so the VM must have at least:

Component Specification
Host CPU Xeon Core 2 virtual cores (2.0 GHz or more)
Host RAM (GB) 12
Host SSD (GB) 128

Windows Server Sensor Specifications

The Windows host into which the Windows Server Sensor is installed must have at least:

Component Specification
Host CPU Xeon Core 2 virtual cores (2.0 GHz or more)
Host RAM (GB) 8
Host SSD (GB) 128
OS Windows Server 2008 R2 (or later)

Enabling SSSE3

Sensors installed on Linux hosts with KVM hypervisors must have SSSE3 enabled for their vCPUs in order to collect network packets (including packets received from a mirror port) and generate Interflow data from them. This is true for both device sensors and server sensors.
SSSE3 is typically supported/enabled for most vCPUs, but may not be for certain legacy AMD vCPUs. See below for instructions on enabling SSSE3.

Similarly, sensors deployed in Hyper-V must have processor compatibility mode disabled to ensure that SSSE3 works correctly. Refer to Installing a Modular, Network, or Security Sensor in Hyper-V for instructions.