Configuring CYRISMA Connectors

Connectors allow Stellar Cyber to collect data from external sources and add it to the data lake. Review the content in this topic to understand what type of data can be collected and acted upon for this connector type.

Connector Overview: CYRISMA

Capabilities

  • Collect: Yes

  • Respond: No

  • Native Alerts Mapped: No

  • Runs on: DP

  • Interval: Configurable

Collected Data

Content Type

Index

API

Vulnerabilities

Syslog, Linux

https://msp.cyrisma.com/app/vulnerability/report/tenants (fetches tenant IDs, tenant access URL, and temporary access token)

https://tenant_access_url/app/vulnerability/report/json (fetches vulnerabilities)

Hosts

Syslog, Assets

Automatically extracted with Vulnerabilities

Domain

https://msp.cyrisma.com/

https://<customer_instance_URL>.cyrisma.com

The <customer_instance_URL> is not provided in the configuration of this connector, but is returned from previous API calls.

Response Actions

N/A

Third Party Native Alert Integration Details

N/A

Required Credentials

  • API Name and API Key

Locating Records

Use the following to query for records:

  • msg_origin.source: cyrisma

  • msg_origin.vendor: cyrisma

  • msg_origin.category: security_scan

  • msg_class: cyrisma_vulnerability

               Let us know if you find the above overview useful.

Adding a CYRISMA Connector

To add a CYRISMA connector:

  1. Obtain credentials and prepare CYRISMA
  2. Add the connector in Stellar Cyber
  3. Test the connector
  4. Verify ingestion

Obtaining Credentials and Preparing CYRISMA

CYRISMA is a SaaS service with MSSP accounts managing data for multiple organizations. Each organization is considered a “tenant” to Stellar Cyber. To support this connector configuration and function:

  • Obtain the MSSP API Name and API Key: These are provided to the MSSP by CYRISMA Customer Support.

  • Add Stellar Cyber Tenant IDs: For any organization that the MSSP wants to retrieve data from CYRISMA, the MSSP must do the following:

    1. Set up a tenant in Stellar Cyber corresponding to each of the organizations in CYRISMA for which they want to collect data.

    2. Access the Stellar Cyber Tenant screen and make note of the ID number associated with each of the organizations.

    3. Access the CYRISMA console (https://msp.cyrisma.com).

    4. Display each organization page and locate the field labeled MDR/XDR Tenant, as shown below.

    5. Click the field and add the tenant ID you obtained from Stellar Cyber.

Adding the Connector in Stellar Cyber

To add the CYRISMA connector in Stellar Cyber:

  1. Log in to Stellar Cyber.

  2. Click System | Integration | Connectors. The Connector Overview appears.

  3. Click Create. The General tab of the Add Connector screen appears. The information on this tab cannot be changed after you add the connector.

  4. Choose Vulnerability Scanner from the Category drop-down.

  5. Choose CYRISMA from the Type drop-down.

  6. For this connector, the supported Function is Collect, which is enabled already.

  7. Enter a Name.

    This field does not accept multibyte characters.

  8. The Tenant Name for this connector is locked as the Root Tenant because the data retrieved with this connector includes the tenant IDs configured in the section above. Data without a tenant ID is skipped. Data with a tenant ID that does not exist in Stellar Cyber is stored in the Root Tenant.

  9. Choose the device on which to run the connector.

    • Certain connectors can be run on either a Sensor or a Data Processor. The available devices are displayed in the Run On menu. If you want to associate your collector with a sensor, you must have configured that sensor prior to configuring the connector or you will not be able to select it during initial configuration. If you select Data Processor, you will need to associate the connector with a Data Analyzer profile as a separate step. That step is not required for a sensor, which is configured with only one possible profile.

    • If the device you're connecting to is on premises, we recommend you run on the local sensor. If you're connecting to a cloud service, we recommend you run on the DP.

  10. (Optional) When the Function is Collect, you can create Log Filters. For information, see Managing Log Filters.

  11. Click Next. The Configuration tab appears.

  12. Enter the API Name you obtained from CYRISMA Customer Support.

  13. In the API Key you obtained from CYRISMA Customer Support.

  14. Enter the Interval (hour). This is how often Stellar Cyber collects information.

    Note that the typical interval for connectors is in minutes. The CYRISMA API supports intervals in hours.

  15. Choose the Content Type. The logs for Vulnerabilities are supported.

  16. Click Next. The final confirmation tab appears.

  17. Click Submit.

    To pull data, a connector must be added to a Data Analyzer profile if it is running on the Data Processor.

  18. If you are adding rather than editing a connector with the Collect function enabled and you specified for it to run on a Data Processor, a dialog box now prompts you to add the connector to the default Data Analyzer profile. Click Cancel to leave it out of the default profile or click OK to add it to the default profile.

    • This prompt only occurs during the initial create connector process when Collect is enabled.

    • Certain connectors can be run on either a Sensor or a Data Processor, and some are best run on one versus the other. In any case, when the connector is run on a Data Processor, that connector must be included in a Data Analyzer profile. If you leave it out of the default profile, you must add it to another profile. You need the Administrator Root scope to add the connector to the Data Analyzer profile. If you do not have privileges to configure Data Analyzer profiles, a dialog displays recommending you ask your administrator to add it for you.

    • The first time you add a Collect connector to a profile, it pulls data immediately and then not again until the scheduled interval has elapsed. If the connector configuration dialog did not offer an option to set a specific interval, it is run every five minutes. Exceptions to this default interval are the Proofpoint on Demand (pulls data every 1 hour) and Azure Event Hub (continuously pulls data) connectors. The intervals for each connector are listed in the Connector Types & Functions topic.

    The Connector Overview appears.

The new connector is immediately active.

Testing the Connector

When you add (or edit) a connector, we recommend that you run a test to validate the connectivity parameters you entered. (The test validates only the authentication / connectivity; it does not validate data flow).

  1. Click System | Integrations | Connectors. The Connector Overview appears.

  2. Locate the connector that you added, or modified, or that you want to test.

  3. Click Test at the right side of that row. The test runs immediately.

    Note that you may run only one test at a time.

Stellar Cyber conducts a basic connectivity test for the connector and reports a success or failure result. A successful test indicates that you entered all of the connector information correctly.

To aid troubleshooting your connector, the dialog remains open until you explicitly close it by using the X button. If the test fails, you can select the  button from the same row to review and correct issues.

The connector status is updated every five (5) minutes. A successful test clears the connector status, but if issues persist, the status reverts to failed after a minute.

Repeat the test as needed.

ClosedDisplay sample messages...

Success !

Failure with summary of issue:

Show More example detail:

 

Verifying Ingestion

To verify ingestion:

  1. Click Investigate | Threat Hunting. The Interflow Search tab appears.

  2. Set the Indices to match the type of content you collected:

    • For Vulnerabilities, change the Indices to Scans.

    • For Host data, change the Indices to Assets.

    The table immediately updates to show ingested Interflow records.